FLIR ADGiLE™

Automated Methane Monitoring Solution with Optical Gas Imaging

The FLIR ADGiLE™ system is an advanced methane detection solution designed to provide continuous and autonomous monitoring of gas leaks. Integrating over a decade of FLIR’s advanced Optical Gas Imaging (OGI) technology, ADGiLE enables operators to quickly identify and address methane emissions. This system significantly reduces the need for manual inspections, offering real-time alerts and visual insights that help users act swiftly to prevent hazards and maintain operational efficiency.
Continuous Operation – Day or Night

Operating 24/7 for continuous monitoring of methane emissions. This continuous monitoring is critical for sites where emissions can occur at any time.

Advanced leak detection analytics to precisely visualize and pinpoint methane emissions, enabling you to detect leaks quickly and efficiently.

Accurately distinguish between operational leaks and fugitive leak emissions to improve safety and operational efficiency.

FLIR ADGiLE™ Automated Methane Monitoring Solution – Full Specifications

Imaging & Optical

IR Resolution 320 × 240 pixels
Thermal Sensitivity / NETD <25 mK at 30°C (86°F)
Spectral Range Uncooled microbolometer: 7.0 µm to 8.5 µm
Detector Pitch 25 µm
Field of View (FOV) 25° × 19°
Focal Length 18 mm (0.71 in)
Focus One-shot contrast, motorized, manual
Image Frequency 30 Hz
Gas Sensitivity [NECL] CH₄: <100 ppm × m (ΔT = 10°C, distance = 1 m)
Minimum Focus Distance Without MSX: 0.3 m (0.98 ft) | With MSX: 0.65 m (2.1 ft)
Spatial Resolution (IFOV) 1.4 mrad/pixel

Measurement & Analysis

Atmospheric Transmission Correction Based on inputs of distance, atmospheric temperature, relative humidity
Emissivity Correction Variable from 0.01 to 1.0
Reflected Apparent Temperature Correction Based on input of reflected temperature
External Optics & Window Correction Based on lens/window transmission and temperature
Object Temperature Ranges & Accuracy Range 1: –20°C to 80°C (±3°C / ±5°F)
Range 2: 0°C to 250°C / 0°C to 100°C (±3°C / ±3%)
Range 3: 100°C to 500°C (±3°C / ±3%)

General Specifications

Housing Material Aluminium
Included Components Thermal camera in protective housing, extra cable glands for auxiliary cables, control cabinet (including Edge PC), adapter bracket, screw kit, power/communication cable, Ethernet RJ45 cable, environmental housing insert, printed documentation including web login credentials.
Size (L × W × H) Camera: 510 mm × 177 mm × 229 mm (20.1 × 6.97 × 9.02 in)
Control Unit (external): 700 mm × 530 mm × 265 mm (27.5 × 20.8 × 10.4 in)
Mounting Plate: 535 mm × 430 mm (21.06 × 16.9 in)
Weight FLIR GF77f 25° + ADGiLE Analytics: 5.90 kg (13.0 lb) | GF77pt 25° + ADGiLE Analytics: 15 kg (33 lb)

Power

External Power Operation Compatible with IEEE 802.3af, IEEE 802.3at/PoE Plus
External Voltage PoE Class 4 (25 W)
Power Consumption 21 W

Environmental & Certifications

Encapsulation IP67 ingress protection
Operating Temperature Range –30°C to 50°C (–22°F to 122°F)
Storage Temperature Range IEC 68-2-1 & IEC 68-2-2: –40°C to 70°C (–104°F to 158°F)
Humidity (Operating & Storage) Relative humidity 5% to 95%
Corrosion Resistance Salty fog resistance: ISO9227 up to 1000 hours
EMC / Compliance EN 55032:2015, EN 55035:2017, FCC Title 47 CFR Part 15:2019, ICES-001 Issue 4:2014

Specifications are subject to change without notice. FLIR ADGiLE™ and related trademarks are trademarks of Teledyne FLIR LLC. :contentReference[oaicite:1]{index=1}