Fixed-Mount Hydrocarbon/VOC Optical Gas Imaging (OGI) Camera

Find gas leaks while meeting governmental and environmental emission goals with the FLIR G620a: a long-lived, cooled OGI camera solution for continuous monitoring at upstream and midstream gas production and processing facilities. The G620a is spectrally filtered to see methane (CH₄), hydrocarbons, and Volatile Organic Compounds (VOCs) with a performance OGI detector that meets sensitivity requirements set forth in U.S. EPA OOOOa and Appendix K. Small and lightweight, the G620a installs quickly and relies on a simplified web interface. Never miss a moment of monitoring thanks to the robust linear cooler which supports 27,000 hours of non-stop operation. The FLIR G620a can help oil and gas companies maintain valuable capital equipment, avoid product loss, meet emissions reduction metrics, and ensure safer work practices.
The high-resolution, high sensitivity cooled image sensor plus the advantage of FLIR’s proprietary High Sensitivity Mode (HSM) allows users to visualize even the smallest gas leaks.
FLIR G620a cameras offer more than 27,000 hours of runtime before any service is required (mean time to failure).
Satisfy U.S. EPA methane and VOC detection sensitivity requirements and achieve global ESG pledges for methane and hydrocarbon reduction.
| IR Resolution | 640 × 512 |
|---|---|
| Thermal Sensitivity (NETD) | < 15 mK at 25°C |
| Spectral Range | 3.2 – 3.4 µm |
| Detector Type | High Operating Temperature (HOT) MWIR T2SLS |
| Detector Pitch | 15 µm |
| Digital Image Enhancement | High Sensitivity Mode (HSM) |
| Field of View (FOV) |
G620a 6°: 6.0° × 4.8° G620a 14.5°: 14.4° × 11.5° G620a 24°: 23.6° × 19.0° |
| Focal Length |
G620a 6°: 92 mm G620a 14.5°: 38 mm G620a 24°: 23 mm |
| Minimum Focus Distance |
G620a 6°: 2 m (6.6 ft) G620a 14.5°: 0.5 m (1.64 ft) G620a 24°: 0.3 m (1.0 ft) |
| Image Frequency | 30 Hz |
| Image Modes | IR image, High Sensitivity Mode (HSM) |
| Zoom | Digital zoom: 1×, 2×, 4×, 8× |
| Video Streaming | Non-radiometric IR video streaming via RTSP (H.264/MJPEG) |
| Radiometric Video/Recording | None |
| Temperature Range | -10°C to 120°C |
|---|---|
| Measurement Accuracy | ≤ 100°C ±2°C, >100°C ±2% of reading |
| Gas Sensitivity (NECL)* |
NECL 1m, ΔT 10°C: Methane: 16 ppm × m Hydrocarbons (Niabara mix): 6.4 ppm × m |
| Ambient Drift Compensation | Yes (factory calibrated) |
| Control Interface | GigE Vision (GenICam); RTSP; Web interface; REST API |
|---|---|
| Digital Inputs | 2× opto-isolated (Vin low: 0–1.5 V, Vin high: 3–25 V) |
| Digital Outputs | 3× opto-isolated outputs (0–48 VDC, max. 350 mA), 1 default NC |
| Synchronization | Sync In |
| Primary Power Source | Power over Ethernet (PoE+) Type 2 (min. 30 W) |
|---|---|
| Optional DC Power | M12 12-pin A-coded male (shared with Digital I/O) |
| Power Consumption | 25 W (cooling) |
| DC Voltage Range | 18 V – 56 V |
| Dimensions (Without Lens) | 200 × 76 × 92 mm (7.9 × 3.0 × 3.6 in) |
|---|---|
| Dimensions (With Lens) |
6° lens: 297 × 99 × 99 mm (11.7 × 3.9 × 3.9 in) 14.5° & 24° lenses: 229 × 76 × 95 mm (9.0 × 3.0 × 3.8 in) |
| Weight |
6°: 1.90 kg (4.14 lb) 14.5°: 1.48 kg (3.22 lb) 24°: 1.50 kg (3.27 lb) |
| Weight (Without Lens) | 1.32 kg (2.91 lb) |
| Operating Temperature Range | -20°C to 50°C (-4°F to 122°F) |
|---|---|
| Encapsulation | IP50 |
| Shock (MIL-STD-810H) | 25 g, 6 ms; half-sine; ±500 shocks (X,Y,Z) |
| Vibration | 10–58 Hz, 0.15 mm; 58–500 Hz, 2 g; 5 cycles, 1 oct/min (X,Y,Z) |
| EMC / Directives | EN55032:2015/A11:2020, EN55035:2017/A11:2020, FCC Part 15 Class A, KC C 9832 & KS C 9835 |
Specifications are subject to change without notice. FLIR and G620a are trademarks of Teledyne FLIR LLC. :contentReference[oaicite:1]{index=1}